loader image
Get Brochure
Flame DetectorFlammable Gas Detector

Flammable Gas Detector DA100

Flammable Gas Detector DA100 is a “SMART” gas detector designed to detect and monitor flammable gases in the air in the range of 0 to 100 % LEL using Catalyst Cell technology.

  • The DA100 is an intelligent electronic device that applies Rezontech’s.
  • unique algorithm and has a user interface and comprehensive fault.
  • diagnosis capabilities.
  • The transmeter design also features Rezontech’s advanced technology.
  • suitable for Catalyst Cells. The gas-sensitive sensor assembly is stainless.
  • steel and the transmeter housing is designed to protect against.
  • corrosion and other effects by coating aluminum with epoxy and with an internal pressure-resistant structure.
Highlights
  • Explosion proof construction for internal pressure can be installed in high risk gas leakage areas.
  • Continuous detection of combustible gases from low up to high concentrations by applying a high sensitivity sensor.
  • Self diagnosis function and various algorithms secure stability and reliability.
  • Measured concentrations and operation status are indicated on the LCD or OLED display.
  • 2 gas alarms, 1 fault displayed and relay contact output.
  • Remote calibration and program settings are available using the Magnet bar.
  • Multiple output options, analog 4 to 20 mA and digital communication signal RS-485, Modbus Compatible.
  • Convenient structure for calibration and maintenance.

Specification

 [ Basic Information ] 

Measuring gas : Combustible gases

(CH4, H2, C4H10, LNG, LPG & etc.)

  • type : Diffusion type
  • sensor : Contact Combustion Formula
  • Measuring range : 0 to 100 % LEL
  • Operating temperature : T6 = -40 to 60℃,
  •                             T4= -40 to 80℃
  • Operating humidity : 0 ~ 95 %
  • Explosion proof class: Ex d IIC T6, T4 (KCs)
  •                    Ex db IIC T6 / T4 Gb (KCs)
  •                    Ex tb IIIC T85℃ / T135℃ Db (IECEx)
  •                    Also Ex db IIC T6 / T4 Gb (ATEX)
  • Water and dust tight : IP66
  • Output signal
  •  – Analog Output Signal : 4 to 20 mA DC (sink or source),
  •   Conductor loop resistance : 600 ohm max. @ 24 VDC
  •  – Digital Output Signal (Option) : RS-485 MODBUS RTU
  •  – Relay (Option) : Alarm1, Alarm2, Fault (3A @ 30 VDC , SPDT)
[ Mechanical ]

  • Material : Housing  / ALDC(Epoxy coating),
  •              Sensor : SUS316
  • Weight : Approx. 1.75 ㎏
  • Dimension : 150 mm (W) × 173 mm (H) × 112 mm (D)

[ Electrical  ]

  • Operating power : 24 VDC (18 to 31 VDC)
  • Power consumption : 2.4 W @ 24 VDC
  •                         Max. : 3 W @ 24 VDC
Certificates and Documents